회사 사건 High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution

High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution

2025-11-16
Latest company cases about High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution

Background

In food cold chain storage systems, pneumatic control valves serve as critical components for regulating refrigeration media. These environments typically feature high humidity, making them prone to pneumatic valve condensate formation when water vapor in compressed air systems condenses inside low-temperature valve bodies. This problem can lead to operational issues such as sluggish actuator movement and frozen sealing components.

최신 회사 사례 High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution  0

Operating Parameters:

  • Application: Cold chain storage systems
  • Product: Pneumatic flanged butterfly valve
  • Medium: Compressed air / Liquid refrigerant
  • Actuator Type: double-acting pneumatic
  • Air Supply Pressure: 0.6–0.8 MPa
  • Ambient Temperature: 2–8°C
  • Relative Humidity: 75–85% RH
  • Valve Material: SUS304
  • Connection: Flange
  • Size: DN50
  • Power Supply: 24VDC
최신 회사 사례 High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution  1

Analysis

Continuous formation of pneumatic valve condensate in actuator air supply lines and valve cavities has led to a series of failures. This accumulation causes frozen solenoid pilot valves, hardened piston seals, and icing on drive shafts. These condensate-related issues result in noticeable signal response delays, loss of sealing performance, significant reduction in actuation torque, and frequent unplanned shutdowns.

  • Technical Principles
  •  Technical analysis reveals that condensate formation stems from the dew point temperature of compressed air. When saturated moist air passes through actuators, instantaneous temperature drops occur at throttling points due to the Joule-Thomson effect, initiating condensate development. In low-temperature environments of 0–10°C, this phenomenon worsens due to:Air supply dew point temperature exceeding ambient temperature
  • Poor pipeline layout hindering pneumatic valve condensate drainage
  • Insulation deficiencies creating localized cold bridges
  • Cyclic operation causing temperature fluctuations that promote condensate
최신 회사 사례 High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution  2

Solutions

  • Air Supply Pipeline Optimization

 Use double-sealed stainless steel piping systems with pressure drop monitoring to prevent pneumatic valve condensate formation. Ensure pressure loss remains ≤0.01 MPa per 10 meters. All connections should feature metal seal structures, with periodic leak detection to monitor potential pneumatic valve condensate issues.

  • Graded Drainage System Design

 Implement a three-stage drainage system specifically for pneumatic valve condensate removal at key points: after the air receiver, before the dryer, and before control valves. Utilize large-capacity float drains, adjustable timer drain valves, and high-efficiency centrifugal separators to effectively manage pneumatic valve condensate at multiple stages.

  • Intelligent Temperature Control and Insulation System

 Establish graded insulation to combat condensate in critical components. Use closed-cell rubber insulation with electric heat tracing for pipelines. Install custom insulation jackets with temperature sensors on valve bodies to maintain surface temperature above dew point and prevent pneumatic valve condensate. Fill actuators with aerogel material to provide comprehensive protection against condensate formation.

  • Precise Environmental Humidity Control

 Deploy rotary dehumidification units in valve cluster areas to maintain ambient dew point temperatures below -15°C, effectively preventing pneumatic valve condensate. Install humidity monitoring systems to activate dehumidification when RH ≥ 60%, controlling conditions that lead to pneumatic valve condensate.

최신 회사 사례 High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution  3

Results

  • Systematic improvement in air quality, achieving ISO 8573-1:2010 Class 2 standards, ensuring dry air supply that prevents pneumatic valve condensate
  • Drastic reduction in failure rates of core control valves, with an 80% year-on-year decrease in condensate-related failures
  • Significant extension of actuator service life, with mean time between failures reaching 38,000 operating hours due to effective control
  • Strategic reduction in annual maintenance costs by 67%, achieved through minimized condensate problems and reduced maintenance requirements
최신 회사 사례 High-Humidity, Low-Temperature - Pneumatic Valve Condensate Meets GRAT Resolution  4

Effective management of pneumatic valve condensate in low-temperature environments is essential for system reliability. Our professional services focus on comprehensive condensate solutions to ensure stability and durability of industrial control systems. We invite industry clients to collaborate on developing advanced prevention strategies for safer, more efficient fluid control solutions.